1.
medrxiv; 2022.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2022.03.24.22272891

ABSTRACT

BackgroundPerformances of rapid antigen diagnostic tests (Ag-RDTs) with nasal self-sampling, and oropharyngeal plus nasal (OP-N) self-sampling, in the Omicron period are unknown. MethodsProspective diagnostic accuracy study among 6,497 symptomatic individuals aged >16 years presenting for SARS-CoV-2 testing at three test-sites. Participants were sampled for RT-PCR (reference test) and received one Ag-RDT to perform unsupervised with either nasal self-sampling (during the emergence of Omicron, and after Omicron share was >90%, phase-1) or with OP-N self-sampling (in a subsequent phase-2; Omicron share >99%). The evaluated tests were Acon Flowflex (Flowflex; phase-1 only), MP Biomedicals (MPBio), and Siemens-Healthineers Clinitest (Clinitest). FindingsDuring phase-1, 45% of Flowflex, 29% of MPBio, and 35% of Clinitest participants were confirmatory testers (previously tested positive by a self-test at own initiative). Overall sensitivities with nasal self-sampling were 79.0% (95% CI: 74.7-82.8%) for Flowflex, 69.9% (65.1-74.4%) for MPBio, and 70.2% (65.6-74.5%) for Clinitest. Sensitivities were substantially higher in confirmatory testers (93.6%, 83.6%, and 85.7%, respectively) than in those who tested for other reasons (52.4%, 51.5%, and 49.5%, respectively). Sensitivities decreased by 6.1 (p=0.16 by Chi-square test), 7.0 (p=0.60), and 12.8 (p=0.025) percentage points, respectively, when transitioning from 29% to >95% Omicron. During phase-2, 53% of MPBio, and 44% of Clinitest participants were confirmatory testers. Overall sensitivities with OP-N self-sampling were 83.0% (78.8%-86.7%) for MPBio and 77.3% (72.9%-81.2%) for Clinitest. Comparing OP-N to nasal sampling, sensitivities were slightly higher in confirmatory testers (87.4% and 86.1%, respectively), and substantially higher in those testing for other reasons (69.3% and 59.9%, respectively). InterpretatioSensitivities of three Ag-RDTs with nasal self-sampling decreased during Omicron emergence but was only statistically significant for Clinitest. Sensitivities were substantially influenced by the proportion of confirmatory testers. Addition of oropharyngeal to nasal self-sampling improved sensitivities of MPBio and Clinitest. FundingDutch Ministry of Health, Welfare, and Sport. Research into contextO_ST_ABSEvidence before this studyC_ST_ABSSARS-CoV-2 rapid antigen diagnostic tests (Ag-RDTs) require no or minimal equipment, provide a result within 15-30 minutes, and can be used in a range of settings including for self-testing at home. Self-testing may potentially lower the threshold to testing and allows individuals to obtain a test result quickly and at their own convenience, which could support the early detection of infectious cases and reduce community transmission. Real world evidence on the performance of unsupervised nasal and oropharyngeal plus nasal (OP-N) self-sampling in the Omicron variant period is needed to accurately inform end-users and policymakers. Therefore, we conducted a large prospective diagnostic accuracy study of three commercially available Ag-RDTs with self-sampling (the Acon Flowflex test, the MP Biomedicals test, and the Siemens-Healthineers Clinitest) during and after the emergence of Omicron using RT-PCR as the reference standard. Our aims were to evaluate whether the accuracies of Ag-RDTs with nasal self-sampling changed over time with the emergence of Omicron; and to determine whether addition of oropharyngeal to nasal self-sampling with the same swab yielded higher diagnostic accuracies. What this study addsThe large comprehensive study was conducted in almost 6,500 participants with symptoms when presenting for routine SARS-CoV-2 testing at three public health service COVID-19 test-sites in the Netherlands. During the study, conducted between 21 December 2021 and 10 February 2022, the percentage of the Omicron variant in samples from the national SARS-CoV-2 pathogen surveillance increased from 29% in the first week to 99% in the last week of the study. The period during which the Omicron variant was dominant was divided into a nasal sampling phase (phase-1; Omicron present in >90% of surveillance samples) and an OP-N sampling phase (phase-2; Omicron share was >99%). In phase-1, 45% of Flowflex, 29% of MPBio, and 35% of Clinitest participants visited the test-site because of a positive self-test (confirmatory testers). Overall sensitivities with nasal self-sampling were 79.0% (95% CI: 74.7-82.8%) for the Flowflex, 69.9% (65.1-74.4%) for the MPBio, and 70.2% (65.6-74.5%) for the Clinitest Ag-RDT. Sensitivities were 94%, 84%, and 86%, respectively, for confirmatory testers, and 52%, 52%, and 50%, respectively, for those who had other reasons for getting tested. Sensitivities were 87.0% (79.7-92.4%), 83.1% (72.9-90.7%), and 80.0% (51.9-95.7%), respectively, in the first week, and decreased by 6.1 (p=0.16 by Chi-square test), 7.0 (p=0.60), and 12.8 (p=0.025) percentage points in the final week of the study. In Phase-2, 53% of MPBio and 44% of Clinitest participants were confirmatory testers. Overall sensitivities with OP-N self-sampling were 83.0% (78.8%-86.7%) for MPBio and 77.3% (72.9%-81.2%) for Clinitest. When comparing OP-N to nasal sampling, sensitivities were slightly higher in confirmatory testers (87.4% and 86.1%, respectively), and substantially higher in those testing for other reasons (69.3% and 59.9%). Implications of all the available evidenceThe sensitivities of three commercially available Ag-RDTs performed with nasal self-sampling decreased during the emergence of Omicron, but this trend was only statistically significant for Clinitest. Addition of oropharyngeal to nasal self-sampling improved the sensitivity of the MPBio and Clinitest, most notably in individuals who visited the test-site for other reasons than to confirm a positive self-test. Based on these findings, the manufacturers of MPBio and Clinitest may consider extending their instructions for use to include combined oropharyngeal and nasal sampling, and other manufacturers may consider evaluating this as well.


Subject(s)
COVID-19
2.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.12.08.21267452

ABSTRACT

BackgroundSARS-CoV-2 self-tests may lower the threshold of testing and produce a result quickly. This could support the early detection of infectious cases and reduce further community transmission. However, the diagnostic accuracy of (unsupervised) self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We therefore conducted a large-scale head-to-head comparison of the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT, each compared to a molecular reference test, in the general population in the Netherlands. MethodsIn this cross-sectional study we consecutively included individuals aged 16 years and older presenting for SARS-CoV-2 testing at three Dutch public health service test sites irrespective of their indication for testing, vaccination status, and symptomatology. Participants were sampled for molecular testing at the test site and received two self-tests (the Hangzhou AllTest saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform at home within a few hours without knowledge of their molecular test result. Information on presence and type of symptoms, user experiences, and results of both self-tests were collected via an online questionnaire. For each self-test, sensitivity, specificity, positive and negative predictive values were determined with molecular testing as reference standard. FindingsThe SARS-CoV-2 molecular reference test positivity rate was 6.5% in the 2,819 participants. Overall sensitivities with 95% confidence intervals were 46.7% (85/182; 39.3%-54.2%) for the saliva Ag-RDT, and 68.9% (124/180; 61.6%-75.6%) for the nasal Ag-RDT. With a viral load cut-off ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, sensitivities increased to 54.9% (78/142; 46.4%-63.3%) for the saliva Ag-RDT and 83.9% (120/143; 76.9%-89.5%) for the nasal Ag-RDT. For the nasal Ag-RDT, sensitivities were 78.5% [71.1%-84.8%] and 22.6% [9.6%-41.1%] in those with and without symptoms at the time of sampling, which increased to 90.4% (113/125; 83.8%-94.9%) and 38.9% (7/18; 17.3%-64.3%) after applying the viral load cut-off. In those with and without prior confirmed SARS-CoV-2, sensitivities were 36.8% [19/372; 16.3%-61.6%] and 72.7% [161/2437; 65.1%-79.4%] for the nasal Ag-RDT, which increased to 100% (7/7; 59.0%-100%) and 83.1% (113/126; 75.7%-89.0%) after applying the viral load cut-off. The diagnostic accuracy of the nasal Ag-RDT did not differ by COVID-19 vaccination status, sex, and age. Specificities were >99%, positive predictive values >70% and negative predictive values >95%, for the saliva Ag-RDT, and >99%, >90%, and >95% for the nasal Ag-RDT, respectively, in most analyses. Interpreting the results was considered (very) easy for both self-tests. InterpretationThe Hangzhou AllTest self-performed saliva Ag-RDT is not reliable for SARS-CoV-2 infection detection overall nor in the studied subgroups. The SD Biosensor self-performed nasal Ag-RDT had high sensitivity in individuals with symptoms and in those without a prior SARS-CoV-2 infection. The overall accuracy in individuals with symptoms was comparable to that found in previous studies with professional sampling for this Ag-RDT. The extremely low sensitivity of the nasal Ag-RDT in asymptomatic individuals and in individuals who had had a prior SARS-CoV-2 infection is an important finding and warrants further investigation. FundingDutch Ministry of Health, Welfare, and Sport.


Subject(s)
COVID-19 , Severe Acute Respiratory Syndrome
3.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.11.19.21266579

ABSTRACT

Objective To assess the diagnostic accuracy of three rapid antigen tests (Ag-RDTs) for detecting SARS-CoV-2 infection in the general population. Design Cross-sectional study with follow-up using pseudonymised record linkage. Setting Three Dutch public health service COVID-19 test sites. Participants Consecutively included individuals aged 16 years and older presenting for SARS-CoV-2 testing. Main outcome measures Sensitivity, specificity, positive and negative predictive values of BD-Veritortm System (Becton Dickinson), PanBio (Abbott), and SD-Biosensor (Roche Diagnostics), applying routinely used sampling methods (combined oropharyngeal and nasal [OP-N] or nasopharyngeal [NP] swab), with molecular testing as reference standard. For SDBiosensor, the diagnostic accuracy with OP-N sampling was also assessed. A viral load cutoff ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL) served as a proxy of infectiousness. Results SARS-CoV-2 prevalence and overall sensitivities with 95% confidence intervals were 188/1441 (13.0%) and 129/188 (68.6% [61.5%-75.2%]) for BD-Veritor, 173/2056 (8.4%) and 119/173 (68.8% [61.3%-75.6%]) for PanBio, and 215/1769 (12.2%) and 160/215 (74.4% [68.0%-80.1%]) for SD-Biosensor with routine sampling, and 164/1689 (9.7%) and 123/164 (75.0% [67.7%-81.4%]) for SD-Biosensor with OP-N sampling. In those symptomatic or asymptomatic at sampling, sensitivities were 72.2%-83.4% and 54.0%-55.9%, respectively. With a viral load cut-off, sensitivities were 125/146 (85.6% [78.9%-90.9%]) for BD-Veritor, 108/121 (89.3% [82.3%-94.2%]) for PanBio, 160/182 (87.9% [82.3%-92.3%]) for SD-Biosensor with routine sampling, and 118/141 (83.7% [76.5%-89.4%]) with OP-N sampling. Specificities were >99%, and positive and negative predictive values >95%, for all tests in most analyses. 61.3% of false negative Ag-RDT participants returned for testing within 14 days (median of 3 days, interquartile range 3) of whom 90.3% tested positive. Conclusions The overall sensitivities of the three Ag-RDTs were 68.6%-75.0%, increasing to at least 85.6% after the viral load cut-off was applied. For SD-Biosensor, the diagnostic accuracy with OP-N and NP sampling was comparable. Over 55% of false negative Ag-RDT participants tested positive during follow-up.


Subject(s)
COVID-19 , Sialic Acid Storage Disease